February, 2008
2-83
WorkCentre 5225, 5230
005-910, 005-911
Status Indicator Raps
Launch Version
005-910 DADF Out Sensor Static Jam
Out Sensor On detected at the timing below:
1. Power On
2. Feeder Cover Interlock Close
3. Platen Interlock Close.
Procedure
If the problem occurs frequently, make sure that there is no obstacle blocking the light path on
Out Sensor. Check the connections between the Out Sensor and the DADF PWB. If OK,
replace the Out Sensor. If the problem persists, replace the DADF PWB (PL 15.3).
005-911 DADF Exit 1 Sensor Static Jam
Exit1 Sensor On detected at the timing below:
1. Power On
2. Feeder Cover Interlock Close
3. Platen Interlock Close.
Procedure
If the problem occurs frequently, make sure that there is no obstacle blocking the light path on
Exit1 Sensor. Check the connections between the Exit1 Sensor and the DADF PWB. If OK,
replace the Exit1 Sensor. If the problem persists, replace the DADF PWB (PL 15.3).