February, 2008
2-675
WorkCentre 5225, 5230
124-326, 124-327
Status Indicator Raps
Launch Version
124-326 IOT Speed Not Registered RAP
Status 1 or 2 of speed registration procedure for IOT is detected when the system is booted.
Procedure
IOT Speed change procedure starts with this fault. User to input SW key for IOT speed change
according to dialog displayed on UI.
124-327 IOT Speed Change SW Failure RAP
Error is detected during IOT Speed change procedure:
Move to Diag Mode fails.
DC132 fails.
SEEP ROM R/W fails.
Rebooting fails.
Procedure
1. Replace IOT
2. Replace Controller board.