February, 2008
2-688
WorkCentre 5225, 5230
124-383, 124-390
Launch Version
Status Indicator Raps
124-383 CRUM Market System 2 (2)
CRUM control failed in system 2.
Procedure
Check the electrical connections on the ESS PWB and MCU PWB. The connectors are securely
connected.
YN
Connect the connectors.
Turn on the power again. The problem persists.
YN
Return to Service Call Procedures.
Perform GP 4, repair the problem by master SYS2.
If the problem persists, replace the ESS PWB (PL 9.2).
124-390 OEM Market (2)
OEM (Original Equipment Manufacturer) CRUM control failed.
Procedure
Check the electrical connections on the ESS PWB and MCU PWB. The connectors are securely
connected.
YN
Connect the connectors.
Turn on the power again. The problem persists.
YN
Return to Service Call Procedures.
Replace the ESS PWB (PL 9.2)
If the problem persists replace the MCU PWB (PL 9.1).