February 2013
6-103
ColorQube® 9303 Family
GP 37, GP 38
General Procedures/Information
Drum Pulley
Refer to PL 94.20 Item 3.
Perform the following procedures in the order shown:
1. dC967 Head to Drum Spacing Check.
2. dC971 Head to Head Alignment Adjustment.
3. dC977 Drum Runout Calibration.
4. dC972 Printhead Uniformity. Select Option 5 Y dot position correction. Select all 4 print-
heads.
IOD Assembly
Refer to PL 94.15 Item 1.
Perform dC971 Head to Head Alignment Adjustment.
Front Guide Track
Refer to PL 94.15 Item 2.
Perform dC971 Head to Head Alignment Adjustment.
Rear Guide Track
Refer to PL 94.15 Item 3.
Perform dC971 Head to Head Alignment Adjustment.
Registration/Pre-heat Assembly
Refer to PL 88.10 Item 1.
Perform dC625 Registration / Preheat Calibration.
Horizontal Paper Path Assembly
Refer to PL 82.15 Item 1.
Perform dC625 Registration / Preheat Calibration.
GP 38 How to Set the Date and Time
Purpose
To set the machines date and time.
Procedure
Perform the following:
1. Enter Customer Administration Tools, GP 5.
2. Press the Machine Status button.
3. Select the Tools tab.
4. Select Device Settings.
5. Select the General folder.
6. Select Date & Time.
7. Set the correct date and time, then select Save.
8. Log out of Customer Administration Tools.