Repairs/Adjustments
REP 12.11-110 Bin 1 Upper Level Sensor
Parts List on PL 12.35.
Removal
WARNING
Switch off the electricity to the machine. Refer to GP 14. Disconnect the power cord
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1. Remove the ejector assembly, REP 12.10-110.
2. Remove the bin 1 upper level sensor, Figure 1.
Figure 1 Removal
Replacement
Reverse the removal procedures to replace the bin 1 level sensor.
2
Disconnect connector.
1
Remove two screws
and harness retainers.
4
Release the
sensor and
disconnect
harness.
3
Remove 2 screws,
remove sensor support
assembly.