Functions specific to SCALANCE
4.2 WBM
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
137
The timeout setting for the WBM is displayed.
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
web-session-timeout
Description
With this command, you enable the automatic logoff and you configure the timeout setting for
the WBM.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call up the command with the following parameters:
web-session-timeout[seconds(60-3600)]
The parameter has the following meaning:
Time in seconds until automatic logout
after the last entry
60 … 3600
The time is configured and automatic logout is enabled.
You disable automatic logoff with the no web-session-timeout command.
You display the current timeout setting with the
show web-session-timeout command.