EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-500

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
73
3.1.8
logout
Description
With this command, you exit the Command Line Interface.
If you are connected to the device via telnet, the session is closed.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logout
Result
The CLI session is ended and the Windows Login prompt is displayed.
3.1.9
ping
Description
With this command, you request a response from a device in the network.
This allows you to check whether or not another node is reachable.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals