Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
815
Syntax
Call up the command with the following parameters:
no rmon collection stats <index (1-52)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
index
Number of the recording
1 ... 52
Result
The recording of statistical data is ended.
12.5.3.3
rmon collection history
Description
With this command, you configure the collection of statistical data of the interface in a
selectable number of recording intervals ("Buckets ") with a specified period.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents