Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
681
11.1.4.2
no role
Description
With this command, you delete a role.
Note
You can only delete a role when the role is not linked to a user.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no role <role-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
role-name
Role name
Enter the name of a role.
Result
The role is deleted.
Further notes
You create a role with the role command.
You show the created roles with the
show roles command.
11.1.4.3
user-account
Description
With this command, you specify a new user. You can also change the password / role of an
already created user.
When you create a local user an entry is generated automatically in the table "External User
Accounts".
Note
You can create up to 16 additional user accounts.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals