Network structures
6.1 VLAN
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
189
Syntax
Call up the command with the following parameters:
switchport acceptable-frame-type{all|tagged}
The parameters have the following meaning:
Parameter
Description
Range of values / note
all
All frames are accepted.
Note:
O
n a ring port only the parameter
"all" is supported.
Default: all
tagged
Untagged frames are discarded. -
Result
The setting is enabled.
Further notes
You can reset the setting to the default with the no switchport acceptable-frame-type
command.
You can display the status of this function and other information with the
show vlan port
config
command.
6.1.3.4
no switchport acceptable-frame-type
Description
With this command, you reset the setting for the types of frames accepted by the interface to
the default value.
The default value is
all.
The interface accepts tagged and untagged frames.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport acceptable-frame-type

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals