Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
90 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
no duplex
Result
The duplex mode of the Interface is reset to the default value.
Further notes
You configure the duplex mode of the interface with the duplex command.
3.1.13.7
lldp
Description
With this command, you enable the sending and receipt of LLDP packets on the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
lldp{transmit|receive}
The parameters have the following meaning:
Parameter
Description
Range of values / note
transmit
The sending of LLDP packets is ena-
bled.
Default: enabled
receive
The receipt of LLDP packets is ena-
bled.
Default: enabled
Note
Enabling both options
When you call this command, you can only select one option.
If you want to enable both options, call up the command again.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals