Layer 3 functions
9.6 RIPv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
604 Configuration Manual, 11/2015, C79000-G8976-C252-10
9.6.4.1
Note_on_layer 3
Note
These commands are available only with layer 3.
9.6.4.2
ip rip default route originate
Description
This command enables the forwarding of a default route.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ip rip default route originate <metric(1-15)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
metric
Value for the metric information.
1 ... 15
Result
The default route is forwarded.
9.6.4.3
no ip rip default route originate
Description
This command disables the distribution of the default routes.