Functions specific to SCALANCE
4.4 Signaling contact
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
142 Configuration Manual, 11/2015, C79000-G8976-C252-10
signaling contact mode
Description
With this command, you specify the reaction of the signaling contact.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call up the command with the following parameters:
signaling-contact mode {conventional | aligned}
The parameters have the following meaning:
An error/fault is displayed by the fault LED and the signaling contact is
opened. When the error/fault state no longer exists, the fault LED goes off
and the signaling contact is closed.
The way the signaling contact works does not depend on the error/fault that
has occurred. The signaling contact can be opened or closed as required
The reaction of the signaling contact is specified.
You display the setting with the show signaling contact command.
signaling-contact status
Description
With this command, you close or open the signaling contact.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#