Network protocols
7.8 SMTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
373
Syntax
Call the command without parameters:
send test mail
Result
An e-mail according to the currently configured SMTP settings was sent.
Further notes
You can display the current SMTP settings with the show events emailserver command.
7.8.2.6
smtp-port
Description
With this command, you configure an SMTP port.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-port <smtp-port(1-65535)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
smtp-port
Value for the SMTP port 1 ... 65535
Default: 25
Result
An SMTP port is configured.
Further notes
You can reset the setting to the default with the no smtp-port command.
You display the setting with the
show smtp-port command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals