Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
409
Syntax
Call the command without parameters:
no ring-redundancy
Result
The ring redundancy function is disabled.
Further notes
You enable the ring redundancy function with the ring-redundancy mode command.
8.4.5.4
ring-redundancy standby
Description
With this command, you enable the standby function.
Requirement
HRP is enabled
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
ring-redundancy standby
Result
The standby function is enabled.
Further notes
You disable the setting with the no ring-redundancy standby command.
You can display the status of this function and other information with the
show ring-
redundancy
command.