Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
540 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
The interface is an IPv6 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 ospf metric <metric>
The parameter has the following meaning:
Parameter
Description
Range of values / note
metric
Value for the metric 1 ... 65535
Default: 10
Result
The metric is specified.
Further notes
You enable OSPFv3 routing with the ipv6 router ospf command.
You can reset the metric to the default with the
no ipv6 ospf metric command.
You display the configuration with the
show ipv6 ospf interface command.
9.3.4.10
no ipv6 ospf metric
Description
With this command, you reset the metric back to the default value.
Note
This command
is available only with layer 3.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals