Network protocols
7.7 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
356 Configuration Manual, 11/2015, C79000-G8976-C252-10
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]]
The parameters have the following meaning:
Name of the SNMP notification
Keyword for a target key -
Type of the SNMP notification
•
Trap
generates a trap
• Inform
generates a log entry or sends
an entry to the log server
Storage type specifies whether the settings remain
following a restart:
•
volatile (volatile):
The settings are lost after a
restart
•
nonvolatile (non-volatile):
The settings are retained after
a restart
The details of the SNMP notifications are configured.
You delete the details of an SNMP group with the no snmp notify command.
You display the configured SNMP notifications with the
show snmp notif command.
You display the configured SNMP target addresses with the
show snmp targetaddr
command.
no snmp notify
Description
With this command, you delete the details of the SNMP notifications.