System time
5.3 SNTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
160 Configuration Manual, 11/2015, C79000-G8976-C252-10
sntp unicast-server
Description
With this command, you configure an SNTP unicast server.
● The addressing mode of the SNTP client is configured as "unicast".
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Call up the command with the following parameters:
sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN>} [port<1025-
36564>][poll<seconds(16-16284)>]
The parameters have the following meaning:
Keyword for an IP address
Value for an IPv4 unicast address Enter a valid IPv4 unicast ad-
dress.
Keyword for a domain name
Domain name (Fully Qualified Domain
Maximum of 100 characters
UDP port of the time server 1025 … 36564
Keyword for the time after which the
time of day is requested again
-
Value for the time in seconds
The SNTP unicast server is configured.
You can reset the setting to the default with the no sntp unicast-server command.
You display this setting and other information with the
show sntp unicast–mode status
command.