Network structures
6.1 VLAN
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
185
Further notes
You delete the VLAN with the no vlan command.
You can display information about the VLAN with the
show vlan command.
6.1.2.10
no vlan
Description
With this command, you delete a VLAN on the device.
Requirement
The VLAN must not be assigned to a physical port.
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameter:
no vlan <vlan-id(2-4094)>
Parameter
Description
Range of values / note
vlan-id
Number of the addressed VLAN
2 ... 4094
The VLAN with number 1 cannot be deleted.
Result
The VLAN is deleted
Further notes
With the vlan command, you create a VLAN on the device.
You can display information about the VLAN with the
show vlan command.
6.1.2.11
vlan range
Description
With this command, you can select several VLANs and configure them together. The
configurations are valid for all selected VLANs.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals