Layer 3 functions
9.7 RIPng (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
613
Requirement
The device supports the routing function
IPv6 and IPv6 routing is activated.
Note
These commands are av
ailable only with layer 3.
9.7.3.1
distance
Description
With this command, you specify the administrative distance for the RIP protocol. This value
is taken into account if routing information is learned from different routing protocols.
The lowest value for the administrative distance "1" means the highest reliability of the
routing information. Routing information from a system with the value "255" is so unreliable
that it is not learnt by the neighbor routers.
Requirement
You are in the RIPng router configuration mode.
The command prompt is as follows:
cli(config-ripng)#
Syntax
Call up the command with the following parameters:
distance dist<1-255> [route-map <name(20)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
dist
The value for the administrative dis-
tance.
1 ... 255
Default: 120
route-map
Keyword for a route map
-
name
Name of the route map
Maximum of 20 characters.
Result
The value for the administrative distance is set.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals