Security and authentication
11.7 Port Based Network Access Control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
753
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
dot1x port-control {auto|force-authorized|force-unauthorized}
The parameters have the following meaning:
Parameter
Description
Range of values / note
auto
Authentication according to IEEE
802.1x is enabled for the interface.
The data traffic via the interface is
permitted or blocked depending on the
authentication result.
-
force-authorized
data traffic via the interface is permitted
without restrictions
Default: force-authorized ena-
bled
force-unauthorized
data traffic via the interface is blocked
-
Result
The port control parameter is configured.
Further notes
You can reset the port control parameter to the default with the no dot1x port-control
command.
You can display the status of this function and other information with the
show
dot1x
command.
11.7.3.13
no dot1x port-control
Description
With this command, you reset the port control parameter of the authenicator to the default
value.
The default value is
force-authorized.
With this, data traffic is permitted without restrictions.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals