System time
5.3 SNTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
155
Syntax
Call up the command with the following parameters:
ntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
Description
+
Time zones to the west of the NTP server time zone
-
Time zones to the east of the NTP server time zone
hh
Number of hours difference
mm
Number of minutes difference
Enter the number of hours and number of minutes with two digits each.
Default: No time difference.
Result
The time difference between the device and the NTP server is configured.
5.3
SNTP Client
This section describes commands relevant for configuration of the SNTP client.
5.3.1
The "show" commands
This section describes commands with which you display various settings.
5.3.1.1
show sntp status
Description
This command shows the settings of the Simple Network Time Protocol.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show sntp status

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals