Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
792 Configuration Manual, 11/2015, C79000-G8976-C252-10
● Loop detection is enabled.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Call the command without parameters:
loopd reaction local
"disable" is activated for the loopd reaction local function.
"disable" is the default after enabling loop detection.
You enable the "no action" reaction with the no loopd reaction local command.
You can display the status of this function and other information with the
show loopd
command.
no loopd reaction local
Description
With this command, you enable the "no action" reaction for a local loop. If a local loop is
detected, this has no effect on the port.
● Loop detection is enabled.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Call the command without parameters:
no loopd reaction local
"no action" is activated for the loopd reaction local function.
"disable" is the default after enabling loop detection.