Load control
10.5 Service classes
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
668 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
flowcontrol {on|off}
The parameters have the following meaning:
Parameter
Description
on
Enables the function
off
Disables the function
Result
The settings for the flow control function are configured.
Further notes
You can display the status of this function with the show flow-control command.
10.5
Service classes
This section describes commands for configuring the assignment tables for service classes
and the Differentiated Services Code Point (DSCP).
10.5.1
The "show" commands
This section describes commands with which you display various settings.
10.5.1.1
show qos cos-map
Description
This command shows assignment table for service classes.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show qos cos-map

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals