Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
494 Configuration Manual, 11/2015, C79000-G8976-C252-10
9.2.4.15
ip ospf transmit-delay
Description
With this command, you specify the time required to transfer and LSA message.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf transmit-delay <seconds (0 - 3600)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Interval in seconds
0 - 3600
Result
The interval is specified.
Further notes
You delete the interval with the no ip ospf transmit-delay command.
9.2.4.16
no ip ospf transmit-delay
Description
With this command, you delete the interval.
Note
This command is available only with layer 3.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals