Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
678 Configuration Manual, 11/2015, C79000-G8976-C252-10
11.1.2
change password
Description
With this command, you change the password of the logged in user.
Requirement
You are logged into the device with a local user account
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
change password <passwd>
The parameter has the following meaning:
Parameter
Description
Range of values / note
passwd
Value for the password Enter the password.
The password must meet the following
password policies:
Password length: at least 8 characters
At least 1 uppercase letter
At least 1 special character
At least 1 number
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
Further notes
You create a user with the user-account command.
You delete a user with the
no user-account command.
You show the created users with the
show user-accounts command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals