Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
811
Note
Conditions for working with alarms
The events assigned to the alarms are configured.
The Remote monitoring function is started with the rmon
command.
Result
The alarm for monitoring a MIB variable is configured.
Further notes
You delete an alarm with the no rmon alarm command.
You display the list of configured RMON alarms with the
show rmon alarms command.
12.5.2.4
no rmon alarm
Description
With this command, you delete an alarm for monitoring a MIB variable.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no rmon alarm <number (1-52)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
number
Number of the alarm to be deleted 1 ... 52
Result
The entry for monitoring a MIB variable is deleted.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals