Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
88 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You disable the blocking of broadcast frames with the no broadcast-block command.
3.1.13.4
no broadcast-block
Description
With this command, you disable the blocking of broadcast frames on an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no broadcast-block
Result
The blocking of broadcast frames is disabled.
Further notes
You enable the blocking of broadcast frames with the broadcast-block command.
3.1.13.5
duplex
Description
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options
here depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals