EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-500

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
94 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
The Interface must be shut down.
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mtu <frame-size(64-9216)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
frame-size
Size of the MTU in bytes 64 ... 9216
Default: 1514
Result
The setting for the size of the MTU is configured.
Further notes
You can shut down the interface with the shutdown command.
You display this setting with the
show interface mtu command.
You display this setting and other information with the
show interfaces command.
3.1.13.11
multicast-block
Description
With this command, you enable the blocking of multicast frames on an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
multicast-block

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals