Layer 3 functions
9.5 VRRPv3 (IPv4 / IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
578 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
vrrp <vrid(1-255)> accept-mode
The parameter has the following meaning:
Parameter
Description
Range of values / note
vrid
ID of the virtual router
1 ... 255
Result
The ping function to virtual IPv6 addresses is enabled.
Further notes
You disable the ping function for virtual IPv6 addresses with the no vrrp accept-mode
command.
You assign IP addresses to a virtual router with the
vrrp associated -ip command.
You can display the status of the function with the
show vrrp3 interface - vrid or with the
show vrrp3 interface command.
9.5.5.2
no vrrp accept-mode
Description
With this command, you disable the ping function for virtual IPv6 addresses on the VRRP3
interface.
Note
This command is available only with layer 3.
Requirement
An IP address is assigned to the virtual router.
You are in the VRRP3 Interface configuration mode.
The command prompt is as follows:
cli(config-vrrp-v3-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals