Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
791
Further notes
You can display the status of this function and other information with the show loopd
command.
See also
Interface identifiers and addresses (Page 39)
12.3.3.2
loopd port reset
Description
With this command, you enable a port that was blocked by loop detection.
Requirement
Loop detection is enabled
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
loopd port reset
Result
The blocked port is enabled again.
Further notes
You disable the setting with the no loopd port reset command.
You can display the status of this function and other information with the
show loopd
command.
12.3.3.3
loopd reaction local
Description
With this command, you activate the "disable" reaction for a local loop. If a local loop is
detected, the port is blocked.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals