Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
688 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-group <user-group-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
user-group-name
Group name
Enter the name of a group.
Result
The link is deleted.
Further notes
You link a group with a role with the user-group command.
You show the created links with the
show user-groups command.
11.1.4.9
username
Description
With this command, you change the password of the factory set default users "user" and
"
admin".
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#