Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
65
Syntax
Call the command without parameters:
show pnio
Result
The current PROFINET IO configuration is displayed.
3.1.1.12
show broadcast-block config
Description
This command shows the broadcast blocking settings for ports.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show broadcast-block config [port <interface-type> <interface-id)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
port
Keyword for a port description
-
interface-type
Type or speed of the interface
Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The broadcast blocking settings for ports are displayed.
3.1.1.13
show unicast-block config
Description
This command shows the unicast blocking settings for ports.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals