Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
535
The parameter has the following meaning:
Parameter
Description
Range of values / note
interval
Interval in seconds 1 ... 65535
Default: 40
The value must be a multiple of the hello interval.
The routers located on the same link must have the
same interval.
Result
The interval is specified.
Further notes
You display the configuration with the show ip ospf interface command.
You enable OSPFv3 routing with the
ipv6 router ospf command.
You can reset the interval to the default with the
no ipv6 ospf dead-interval command.
9.3.4.4
no ipv6 ospf dead-interval
Description
With this command, you reset the interval to the default value.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv6 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ipv6 ospf dead-interval

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals