Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
685
Result
A link in the table "External User Accounts" has been created.
Note
User name cannot be changed
After creating a user, the user name can no longer be modified. If a user name needs to be
changed, the user must be deleted and a new user created.
Further notes
You delete a link with the no user-account-ext command.
You show the links in the table "External User Accounts" with the
show user-accounts
external
command.
11.1.4.6
no user-account-ext
Description
With this command, you delete the link between a user and a role in the table "External User
Accounts".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-account-ext <user-name-ext>
The parameter has the following meaning:
Parameter
Description
Range of values / note
user-name-ext
User name
Enter the name of a user.
Result
The link in the table "External User Accounts" has been deleted.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals