EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-500

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #768 background imageLoading...
Page #768 background image
Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
768 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
add log <log entry>
The parameter has the following meaning:
Parameter
Description
Range of values / note
log entry
Entry in the logbook
max. 150 characters
Result
The entry has been made in the logbook.
12.1.6.2
client config
Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog: sends the messages to the Syslog server
trap: sends the messages as SNMP trap to a configured recipient
email: sends the messages as e-mail
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
Description
syslog
Enables the client that sends the messages to the Syslog server
trap
Enables the client that sends the SNMP traps
email
Enables the client that sends the e-mails
all
Enables all clients at once

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals