System time
5.1 System time setting
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
149
Syntax
Call up the command with the following parameters:
time dst date <name(16> <year (1900-2099)> begin <MMDDhh> end <MMDDhh>
The parameters have the following meaning:
Parameter
Description
Range of values / note
name
Name of the entry
maximum 16 characters
year
Year 1900 ... 2099
begin
Keyword for the start of daylight saving
time.
-
MMDDhh
Time for the start of daylight saving
time.
Time in the format
MM Month
DD Day
hh Hour
end
Keyword for the end of daylight saving
time.
-
MMDDhh
Time for the end of daylight saving
time.
Time in the format
MM Month
DD Day
hh Hour
Result
The entry for the start and end of daylight saving time was created.
5.1.2.4
time dst recurring
Description
With this command, you configure the start and end of daylight saving time with a generic
description.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals