Layer 3 functions
9.6 RIPv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
596 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
distance dist<1-255> [route-map <name(20)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
dist
The value for the administrative dis-
tance.
1 ... 255
Default: 120
route-map
Keyword for a route map -
name
Name of the route map
Maximum of 20 characters.
Result
The value for the administrative distance is set.
Further notes
You reset the administrative distance to the default with the no distance command.
9.6.3.5
no distance
Description
This command resets the administrative distance to the default (120).
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#
Syntax
Call up the command with the following parameters:
no distance [route-map <name(20)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
route-map
Keyword for a route map
-
name
Name of the route map
Maximum of 20 characters.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals