Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
240 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
no spanning-tree auto-edge
Result
The automatic discovery of a bridge on the interface is disabled.
Further notes
The automatic discovery of a bridge on the interface is enabled with the spanning-tree auto-
edge
command.
6.3.5.7
spanning-tree bpdu-transmit
Description
With this command, you enable or disable the BPDU transmit status at the port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdu-transmit{enabled|disabled}
The parameters have the following meaning:
Parameter
Description
Range of values / note
enabled
BPDU packets are transmitted at the
port
Default: enabled
disabled
BPDU packets are not transmitted at
the port
-
Result
The BPDU transmit status has switched over.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals