Security and authentication
11.3 MAC access control list
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
702 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You disable the setting with the no mac access-group command.
You display the statistical data of the access control list with the
show access-lists
command.
11.3.3.2
no mac access-group
Description
With this command, you disable the access control of the packets of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no mac access-group <access-list-number(1-128)>{in|out}
The parameters have the following meaning:
Parameter
Description
Range of values / note
access-list-number
Number of the access control list
1 ... 128
in
Specifies that incoming packets are
filtered
-
out
Specifies that outgoing packets are
filtered
-
Result
The packet filtering according to the access control list (ACL) is canceled.
Further notes
You enable the setting with the mac access-group command.
You display the configuration of the access control list with the
show access-lists command.