Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
770 Configuration Manual, 11/2015, C79000-G8976-C252-10
12.1.6.4
event config
Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is aRemote Monitoring alarm (RMON alarm)
Message when there is a status change in the power supply
Message when there is a status change in the redundancy manager (RM)
Message when there is a status change on a standby connection
Message when there is a status change in the error monitoring
Message when there is a change in the spanning tree
Message on status change of the VRRP routers
Message if there is a status change in the detection of network loops
Message on status change of OSPF routers
These messages can be processed by the clients in different ways:
Entry in the logbook of the device
Sending the message to the Syslog server
Sending an e-mail
Sending an SNMP trap
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals