Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
770 Configuration Manual, 11/2015, C79000-G8976-C252-10
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is aRemote Monitoring alarm (RMON alarm)
● Message when there is a status change in the power supply
● Message when there is a status change in the redundancy manager (RM)
● Message when there is a status change on a standby connection
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message on status change of the VRRP routers
● Message if there is a status change in the detection of network loops
● Message on status change of OSPF routers
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the Syslog server
● Sending an e-mail
● Sending an SNMP trap
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#