Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
248 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree mst hello-time <seconds(1-2)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Time after which the bridge sends its
configuration frames (BPDUs)
1 ... 2
Default: 2
Result
The setting for the hello time is configured.
Further notes
You can reset the setting for the hello time to the default with the no spanning-tree mst
hello-time
command.
You display this setting and other information with the commands that start with
show
spanning tree ...
.
6.3.5.19
no spanning-tree mst hello-time
Description
With this command, you reset the hello time after which the bridge sends its configuration
BPDUs to the default value.
The default value is 2 seconds.
Requirement
You are in the interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree mst hello-time

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals