EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-500

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #814 background imageLoading...
Page #814 background image
Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
814 Configuration Manual, 11/2015, C79000-G8976-C252-10
12.5.3.1
rmon collection stats
Description
With this command, you start the recording of statistical data of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
rmon collection stats <index (1-52)>[owner<ownername(127)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
index
Number of the recording
1 ... 52
owner
User to which the event is assigned
-
ownername
User name of the user
max. 127 characters
Result
The recording of statistical data is started.
Further notes
You can display the content of a recording with the show rmon statistics command.
12.5.3.2
no rmon collection stats
Description
With this command, you end the recording of statistical data of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals