Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
788 Configuration Manual, 11/2015, C79000-G8976-C252-10
12.3.2.2
no loopd
Description
With this command, you disable the loop detection function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no loopd
Result
The loop detection function is disabled
Further notes
You enable the function with the loopd command.
You can display the status of this function and other information with the
show loopd
command.
12.3.2.3
loopd vlan mode
Description
With this command, you enable the loop detection function for VLAN.
Requirement
Loopd is activated
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
loopd vlan mode