Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
89
Requirement
Autonegotiation is disabled.
You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
Parameter
Description
Range of values / note
full
The Interface will be operated in full
duplex mode.
Default: full
half
The Interface will be operated in half
duplex mode
-
Result
The duplex mode of the interface is configured.
Further notes
You can reset the duplex mode of the Interface to the default value with the no duplex
command.
You disable autonegotiation with the
no negotiation command.
3.1.13.6
no duplex
Description
With this command, you reset the duplex mode of an interface to the default value.
The default value is
full.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals